Ctek MXTS 70 50 User Manual Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 9
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
10 • EN
SUPPORT
CTEK offers a professional customer support: www.ctek.com.
For latest user manual see www.ctek.com.
By e-mail: [email protected],bytelephone:+46(0)22535180,
byfax+46(0)22535195.
CTEK PRODUCTS ARE PROTECTED BY
CHARGING PROGRAMS
STEP 1 DESULPHATION
Detects sulphated batteries. Pulsing current and voltage, removes sulfates from
the lead plates of the battery restoring the battery capacity.
STEP 2 SOFT START
Tests if the battery can accept charge. This step prevents charging a defect battery.
STEP 3 BULK
Charging with maximum current until approximately 80% battery capacity.
STEP 4 ABSORPTION
Charging with declining current to maximize up to 100% battery capacity.
STEP 5 ANALYSE
Tests if the battery can hold charge. Batteries that can not hold charge may need
to be replaced.
STEP 6 RECOND
Choose the Ca/Ca program to add the recondition step to the charging program.
This step can also be selected separately by choosing the BOOST-program. During
the recondition step voltage increases to create controlled gassing in the battery.
Gasing mixes the battery acid and gives back energy to the battery.
STEP 7 FLOAT
This step maintains the battery voltage by providing a constant voltage charge. This
step can also be selected separately by choosing the SUPPLY-program and then it
is possible to select different voltage settings.
STEP 8 PULSE
Maintaining the battery at 95–100% capacity. The charger monitors the battery
voltage and gives a pulse when necessary to keep the battery fully charged.
DESULPHATION SOFT START BULK ABSORPTION ANALYSE RECOND FLOAT PULSE
VOLTAGE (V)
1
1
7
2 3 4 5 6 8
CURRENT (A)
NORMAL
15.8V
31.6V
50A until
12.6V
25.2V
Increasing voltage to
14.4V
28.8V
50A
14.4V
28.8V
Declining current
Checks if voltage
drops to below
12V
24V
13.6V
27.2V
Max 50A
12.7–14.4V
25.4–28.8V
50–2A
AGM
15.8V
31.6V
50A until
12.6V
25.2V
Increasing voltage to
14.7V
29.4V
50A
14.7V
29.4V
Declining current
Checks if voltage
drops to below
12V
24V
13.6V
27.2V
Max 50A
12.7–14.4V
25.4–28.8V
50–2A
Ca/Ca
15.8V
31.6V
50A until
12.6V
25.2V
Increasing voltage to
14.7V
29.4V
50A
14.7V
29.4V
Declining current
Checks if voltage
drops to below
12V
24V
Max 15.8V
Max 31.6V
1.5A
13.6V
27.2V
Max 50A
12.7–14.4V
25.4–28.8V
50–2A
BOOST
Increasing voltage to
15.8V
31.6V
1.5A
Selectable timer,
Initially 8h. Max 24h.
SUPPLY
Selectable
13.6;14.0;
14.4; 14.8V
27.2; 28.0
28.8; 29.2V
70A**
Time limit: 8 hours 20 hours 8 hours 3 minutes
2 hours or 6 hours
depending on
battery voltage at
charge start
10 days* Max 1h pulse
*) SUPPLY program is not time limited
**)For12Vonly,maxcurrentisdeliveredfor30secondsfollowedbya90secondresttime.
The30secondcounterstartswhencurrenthasexceeded50A.50Aisdeliveredcontinuously.
20019214A
2012–0530
Patents Designs Trade marks
EP10156636.2pending RCD 509617 TMA 669987
US12/780968 pending US D575225 CTM844303
EP1618643 USD580853 CTM372715
US7541778 USD581356 CTM3151800
EP1744432 US D571179 TMA823341
EP1483817pending RCD321216 CTM1025831
SE524203 RCD000911839 CTM 405811
US7005832B2 RCD 081418 CTM830545751pending
EP1716626 pending RCD 001119911-0001 CTM1935061pending
SE526631 RCD 001119911-0002 V28573IP00
US7638974B2 RCD 081244 CTM 2010004118 pending
EP09180286.8 pending RCD321198 CTM 4-2010-500516
US12/646405 pending RCD321197 CTM410713
EP1483818 ZL200830120184.0 CTM 2010/05152 pending
SE1483818 ZL200830120183.6 CTM1042686
US76297 74B2 RCD001505138-0001 CTM 766840 pending
EP09170640.8 pending RCD000835541-0001
US12/564360pending RCD000835541-0002
SE528232 D596126
SE525604 D596125
RCD001705138-0001
USD29/378528pending
ZL201030618223.7
USRE42303
USRE42230
20019214A Manual MXTS70, All languages, Print file_003.indd 10 2013-08-19 13:22:24
Page view 8
1 2 3 4 5 6 7 8 9

Comments to this Manuals

No comments